Service upgrade fails for Apps

Description

The service upgrade might fail for Apps with the following logs:

Error: [failed to wait for application argocd/ba: timed out waiting for the condition, error waiting for components [] to be synced affecting their dependencies: [failed to wait for application argocd/ba: timed out waiting for the condition]]
Error: [failed to wait for application argocd/ba: timed out waiting for the condition, error waiting for components [] to be synced affecting their dependencies: [failed to wait for application argocd/ba: timed out waiting for the condition]]

This issue happens when ArgoCD cannot invalidate the cache, causing MongoDB to remain in scaled-down state.

Solution

To fix this issue, you must take the following steps:

  1. Scale up MongoDB:
     kubectl scale deploy -n mongodb mongodb-kubernetes-operator --replicas=1
      kubectl rollout status deploy -n mongodb mongodb-kubernetes-operator
      kubectl rollout status sts -n mongodb mongodb-replica-set
     kubectl scale deploy -n mongodb mongodb-kubernetes-operator --replicas=1
      kubectl rollout status deploy -n mongodb mongodb-kubernetes-operator
      kubectl rollout status sts -n mongodb mongodb-replica-set
    
  2. Check if MongoDB pods are up and healthy:
    kubectl get pods -n mongodb -l app=mongodb-replica-set-svc
    kubectl get pods -n mongodb -l app=mongodb-replica-set-svc
    
  3. Once MongoDB pods are up and running, you can re-run the service upgrade.